Vis enkel innførsel

dc.contributor.authorBøe, Andreas Sæter
dc.contributor.authorFriquin, Kathinka Leikanger
dc.contributor.authorBrandon, Daniel
dc.contributor.authorSteen-Hansen, Anne Elise
dc.contributor.authorErtesvåg, Ivar Ståle
dc.date.accessioned2024-01-04T10:28:31Z
dc.date.available2024-01-04T10:28:31Z
dc.date.created2023-10-20T09:44:30Z
dc.date.issued2023
dc.identifier.issn0379-7112
dc.identifier.urihttps://hdl.handle.net/11250/3109789
dc.description.abstractCross-laminated timber (CLT) is becoming increasingly popular due to its many advantages. However, it has been shown that exposed CLT can have a significant effect on fire dynamics and spread rates. Further studies are therefore needed to better understand the impact of CLT to fire safety. Two large-scale CLT compartment fire experiments (95 m2) representing a modern office building have been performed, #FRIC-01 and #FRIC-02. This paper presents the second experiment, #FRIC-02, with exposed CLT on the back wall and the ceiling. The fire developed fast and spread across the room in less than 3.5 min from ignition of the wood crib on the floor and in 1.5 min after the ignition of the ceiling. Large external flames were observed, despite the compartment being well-ventilated. The 5-layer CLT, which comprised a 40 mm thick exposed outer layer and was face-bonded using a common European polyurethane adhesive, exhibited glue-line integrity failure and led to a second flashover after a significant period of decay. Subsequent layers of 20 mm also delaminated before the fire was manually extinguished after 3 h. Compared to #FRIC-01, the fire spread rate was faster, and temperatures, charring rates, heat release rates and external flames were higher.en_US
dc.language.isoengen_US
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.subjectCLTen_US
dc.subjectFire spreaden_US
dc.subjectLarge-scaleen_US
dc.subjectCompartment fireen_US
dc.subjectSecond flashoveren_US
dc.subjectDelaminationen_US
dc.subjectFacade fireen_US
dc.subjectExternal flameen_US
dc.titleFire spread in a large compartment with exposed cross-laminated timber and open ventilation conditions: #FRIC-02 - Exposed wall and ceilingen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.rights.holder© 2023 The Authorsen_US
dc.source.volume141en_US
dc.source.journalFire safety journalen_US
dc.identifier.doi10.1016/j.firesaf.2023.103986
dc.identifier.cristin2186629
dc.source.articlenumber103986en_US
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode2


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse 4.0 Internasjonal