dc.contributor.author | Wiik, Marianne Rose Kjendseth | |
dc.contributor.author | Sørensen, Åse Lekang | |
dc.contributor.author | Selvig, Eivind | |
dc.contributor.author | Cervenka, Zdena | |
dc.contributor.author | Fufa, Selamawit Mamo | |
dc.contributor.author | Andresen, Inger | |
dc.date.accessioned | 2017-11-22T07:39:33Z | |
dc.date.available | 2017-11-22T07:39:33Z | |
dc.date.created | 2017-10-27T12:26:13Z | |
dc.date.issued | 2017 | |
dc.identifier.isbn | 978-82-536-1555-4 | |
dc.identifier.issn | 1893-157X | |
dc.identifier.issn | 1893-1561 | |
dc.identifier.uri | http://hdl.handle.net/11250/2467440 | |
dc.description.abstract | This report describes the new ZEB Campus Evenstad pilot administration and educational building. The report summarizes and documents the as-built phase life cycle greenhouse gas (GHG) emissions of the administration and educational building at a ZEB-COM ambition level. The ZEB-COM ambition level means that all emissions from construction (C), operational energy (O), and materials (M) are compensated for through on-site, renewable energy production. The report describes the building design and calculation methodology, including operational energy performance and embodied GHG emission calculations from materials and construction. The as-built emission results are then presented, together with a ZEB emission balance. The results are discussed in terms of construction emissions, operational energy use, and material emissions before the conclusion is presented. | |
dc.description.sponsorship | Acknowledgement. This report has been written within the Research Centre on Zero Emission Buildings (ZEB). The authors gratefully acknowledge the support from the Research Council of Norway, BN L – Federation of construction industries, Brødrene Dahl, ByBo, DiBK – Norwegian Building Authority, Caverion Norge AS, DuPont, Entra, Forsvarsbygg, Glava, Husbanken, Isola, Multiconsult, NorDan, Norsk Teknologi, Protan, SAPA Building Systems, Skanska, Snøhetta, Statsbygg, Sør-Trøndelag Fylkeskommune, and Weber. | |
dc.language.iso | eng | |
dc.publisher | SINTEF akademisk forlag | |
dc.relation.ispartofseries | ZEB Project report;36 | |
dc.subject | Zero Emission Buildings | |
dc.subject | Case study | |
dc.subject | Evaluation | |
dc.title | ZEB Pilot Campus Evenstad. Administration and educational building. As-built report | |
dc.type | Research report | |
dc.description.version | publishedVersion | |
dc.rights.holder | © 2017 SINTEF Academic Press and Norwegian University of Science and Technology | |
dc.subject.nsi | VDP::Technology: 500 | |
dc.source.pagenumber | 75 | |
dc.source.issue | 36 | |
dc.identifier.cristin | 1508316 | |
cristin.unitcode | 7401,30,20,0 | |
cristin.unitcode | 7401,30,40,0 | |
cristin.unitname | Bygninger og installasjoner | |
cristin.unitname | Arkitektur, byggematerialer og konstruksjoner | |
cristin.ispublished | true | |
cristin.fulltext | original | |