Show simple item record

dc.contributor.authorSmilden, Emil
dc.contributor.authorSørum, Stian Høegh
dc.contributor.authorBachynski, Erin Elizabeth
dc.contributor.authorSørensen, Asgeir Johan
dc.contributor.authorAmdahl, Jørgen
dc.date.accessioned2024-07-18T11:33:20Z
dc.date.available2024-07-18T11:33:20Z
dc.date.created2020-02-11T23:47:00Z
dc.date.issued2020-02-05
dc.identifier.issn1095-4244
dc.identifier.urihttps://hdl.handle.net/11250/3142146
dc.description.abstractThe cost of offshore wind energy can be reduced by incorporating control strategies to reduce the support structures' load effects into the structural design process. While effective in reducing the cost of support structures, load‐reducing controls produce potentially costly side effects in other wind turbine components and subsystems. This paper proposes a methodology to mitigate these side effects at the wind farm level. The interaction between the foundation and the surrounding soil is a major source of uncertainty in estimating the safety margins of support structures. The safety margins are generally closely correlated with the modal properties (natural frequencies, damping ratios). This admits the possibility of using modal identification techniques to reassess the structural safety after installing and commissioning the wind farm. Since design standards require conservative design margins, the post‐installation safety assessment is likely to reveal better than expected structural safety performance. Thus, if load‐reducing controls have been adopted in the structural design process, it is likely permissible to reduce the use of these during actual operation. Here, the probabilistic outcome of such a two‐stage controls adaptation is analyzed. The analysis considers the structural design of a 10 MW monopile offshore wind turbine under uncertainty in the site‐specific soil conditions. Two control strategies are considered in separate analyses: (a) tower feedback control to increase the support structure's fatigue life and (b) peak shaving to increase the support structure's serviceability capacity. The results show that a post‐installation adaptation can reduce the farm‐level side‐effects of load‐reducing controls by up to an order of magnitude.en_US
dc.language.isoengen_US
dc.titlePost‐installation adaptation of offshore wind turbine controlsen_US
dc.typeJournal articleen_US
dc.typePeer revieweden_US
dc.description.versionpublishedVersionen_US
dc.rights.holder© 2020 The Authors. Wind Energy published by John Wiley & Sons Ltden_US
dc.source.journalWind Energyen_US
dc.identifier.doi10.1002/we.2467
dc.identifier.cristin1793308
cristin.unitcode7566,7,0,0
cristin.unitnameEnergi og transport
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode2


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record