Vis enkel innførsel

dc.contributor.authorLøvald, Sarah Margrethe
dc.contributor.authorConta, Simone
dc.date.accessioned2024-02-13T08:54:11Z
dc.date.available2024-02-13T08:54:11Z
dc.date.created2024-01-29T08:53:00Z
dc.date.issued2024
dc.identifier.isbn978-88-88942-67-4
dc.identifier.urihttps://hdl.handle.net/11250/3117152
dc.description.abstractExcessive sound levels of preterm infants may contribute to negative physiological effects. Yet, recommended sound level limits are consistently exceeded at neonatal intensive care units (NICU), both inside and outside of the incubator. We present the results of a measurement campaign at two Norwegian hospitals with different design of the NICU. The first hospital had a shared unit with several incubators in one room while the second one featured single patient room. Sound pressure levels were measured continuously for several days inside of an unoccupied incubator and outside several active incubators. Additionally, sound pressure levels of an incubator were measured in a quiet room for several operation modes. The sound levels at both hospitals exceeded the recommended limit values. Although the incubator provides considerable attenuation of the environmental sound, the sound level inside the incubator was dominated by the contribution of the machine itself and exceeded the recommended limit values considerably. We conclude that the design of the NICU has some effect on the sound levels inside the incubator. However, without reducing the sound levels from the incubator itself, such measures have a minor effect on the infant exposure to excessive sound levels.en_US
dc.language.isoengen_US
dc.publisherEuropean Acoustics Association (EAA)en_US
dc.relation.ispartofProceedings of the 10th Convention of the European Acoustics Association Forum Acusticum 2023. Politecnico di Torino Torino, Italy, September 11 - 15, 2023
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.subjectNeonatal intensive care uniten_US
dc.subjectSound conditionsen_US
dc.subjectIncubator noiseen_US
dc.subjectUnit layout effecten_US
dc.titleComparative analysis of the sound conditions at the neonatal intensive care units of two Norwegian hospitalsen_US
dc.typeChapteren_US
dc.description.versionpublishedVersionen_US
dc.rights.holder© S.M. Løvald et al.en_US
dc.source.pagenumber4869-4872en_US
dc.identifier.doi10.61782/fa.2023.0503
dc.identifier.cristin2236431
cristin.ispublishedtrue
cristin.fulltextoriginal


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse 4.0 Internasjonal