dc.description.abstractExposing cross-laminated timber (CLT) structures in buildings is increasingly popular in modern buildings. However, large timber surfaces, window facades, and different geometries can change the fire dynamics in a compartment. The effect of those parameters, therefore, needs to be studied. Two large-scale CLT compartment fire experiments (95 m2) have consequently been performed. The experiments were designed to represent a modern office building with an open-plan space and large window openings. In this experiment, #FRIC-01, the ceiling was exposed. The wood crib fire developed slowly and travelled approximately 1.5 m before the ceiling ignited at 32.5 min. Thereafter the fire spread rapidly across the ceiling and wood crib before it shortly after retracted. Three such cycles of rapid spread followed by a retraction occurred within 13 min, whereby the wood crib fire grew larger for each cycle. After the flames extended through the compartment for the fourth time, the fire remained fully developed. After a short period of intense burning, the CLT self-extinguished while the wood crib fire was still burning. The compartment withstood full burnout, and no reignition occurred despite some delamination and using an adhesive that lacks a demonstrated resistance against glue-line integrity failure.en_US
dc.language.isoengen_US
dc.publisherElsevieren_US
dc.rightsCC BY 4.0*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectCLTen_US
dc.subjectFire spreaden_US
dc.subjectSelf-extinctionen_US
dc.subjectLarge-scaleen_US
dc.subjectCompartment fireen_US
dc.titleFire spread in a large compartment with exposed cross-laminated timber and open ventilation conditions: #FRIC-01 – Exposed ceilingen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.rights.holder© 2023 The authorsen_US
dc.subject.nsiVDP::Teknologi: 500en_US
dc.source.volume140en_US
dc.source.journalFire safety journalen_US
dc.identifier.doi10.1016/j.firesaf.2023.103869
dc.identifier.cristin2164178
dc.relation.projectNorges forskningsråd: 294649en_US
dc.source.articlenumber103869en_US
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode2


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

CC BY 4.0
Med mindre annet er angitt, så er denne innførselen lisensiert som CC BY 4.0