Vis enkel innførsel

dc.contributor.authorSørensen, Åse Lekang
dc.contributor.authorLudvigsen, Bjørn
dc.contributor.authorAndresen, Inger
dc.date.accessioned2023-04-25T14:27:48Z
dc.date.available2023-04-25T14:27:48Z
dc.date.created2023-04-23T22:28:17Z
dc.date.issued2023
dc.identifier.issn0306-2619
dc.identifier.urihttps://hdl.handle.net/11250/3064999
dc.description.abstractThe number of EVs is increasing globally. In cold climates, it is generally recommended to use electricity from the grid to preheat the EV cabin before using the car, to extend driving ranges, to ensure comfort, and for safety. A majority of such preheating sessions are happening in the morning hours during the winter, when there is also a high demand for other energy use. It is thus important to understand the power loads for grid-connected preheating of EV cabins. This work presents an experimental study, with 51 preheating sessions of five typical EV models during different outdoor temperatures. The results of the study showed that during the preheating sessions, most of the EVs had a power use of between 3 and 8 kW initially, which was reduced to about 2 to 4 kW after a 10 to 20 min initial period. For most of the sessions, the preheating lasted between 15 and 45 min. The preheating energy use was found to be up to 2 kWh for most EVs, with a maximum of 5 kWh. Multiple linear regression models were developed, to investigate the relationship between various variables and the energy use for preheating. Finally, hourly energy loads for EV cabin preheating were compared to other energy loads in apartment buildings. The power and energy loads for preheating EV cabins are affected by a number of parameters, such as the specific EV, charge point, preheating duration, temperature levels, and user habits.en_US
dc.language.isoengen_US
dc.publisherElsevieren_US
dc.relation.urihttps://doi.org/10.1016/j.apenergy.2023.121054
dc.rightsCC BY 4.0*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectEnergibruken_US
dc.subjectEnergy useen_US
dc.subjectElbilen_US
dc.subjectElectric vehicleen_US
dc.subjectElectric vehiclesen_US
dc.subjectLow temperatureen_US
dc.subjectCabin preheatingen_US
dc.subjectPower monitoringen_US
dc.subjectMultiple linear regressionen_US
dc.subjectNon-flexible energy loaden_US
dc.titleGrid-connected cabin preheating of Electric Vehicles in cold climates – A non-flexible share of the EV energy useen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.subject.nsiVDP::Matematikk og naturvitenskap: 400en_US
dc.subject.nsiVDP::Mathematics and natural scienses: 400en_US
dc.source.volume341en_US
dc.source.journalApplied Energyen_US
dc.identifier.doihttps://doi.org/10.1016/j.apenergy.2023.121054
dc.identifier.cristin2142703
dc.relation.projectNorges forskningsråd: 272402en_US
dc.relation.projectNorges forskningsråd: 257660en_US
dc.source.articlenumber121054en_US
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

CC BY 4.0
Med mindre annet er angitt, så er denne innførselen lisensiert som CC BY 4.0