Vis enkel innførsel

dc.contributor.authorWold, Jens Petter
dc.contributor.authorO'Farrell, Marion
dc.contributor.authorAndersen, Petter Vejle
dc.contributor.authorTschudi, Jon
dc.date.accessioned2023-02-15T16:04:56Z
dc.date.available2023-02-15T16:04:56Z
dc.date.created2021-04-12T10:37:25Z
dc.date.issued2021
dc.identifier.citationFoods. 2021, 10 (4), 828.en_US
dc.identifier.issn2304-8158
dc.identifier.urihttps://hdl.handle.net/11250/3051218
dc.description.abstractDry matter (DM) content is one of the most important quality features of potatoes. It defines the physical properties of the potatoes and determines what kind of product the potatoes can be used for. This paper presents the results obtained by a novel prototype NIR (near-infrared) instrument designed to measure DM content in single potatoes in process. The instrument is based on interaction measurements to measure deeper into the potatoes. It measures rapidly, up to 50 measurements per second, allowing several moving potatoes to be measured per second. The instrument also enables several interactance distances to be recorded for each measurement. The instrument was calibrated based on three different potato varieties and the calibration measurements were done in a process plant, making the calibration model suitable for in-line use. A good calibration for DM was obtained by partial least squares regression (RMSECV = 0.78% DM, R2 = 0.91). The instrument was tested in-line in the process plant and several batches of potatoes were monitored for the estimation of the DM distribution per batch. Accuracy of DM determination as function of measurement position on the potato was studied, and results indicate that NIR scans along the center part of the potatoes give slightly better results compared to scans taken on either side of the center. Small differences in optical measurement geometry influence the accuracy of the calibration models, underlining the importance of optimizing instrument design for successful measurementsen_US
dc.language.isoengen_US
dc.publisherMDPIen_US
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.subjectDry matteren_US
dc.subjectDry matteren_US
dc.subjectPotatoen_US
dc.subjectPotatoen_US
dc.subjectInline NIRen_US
dc.subjectInline NIRen_US
dc.subjectInteraksjonen_US
dc.subjectInteractionen_US
dc.subjectNear infrared spectroscopyen_US
dc.subjectNærinfrarød spektroskopien_US
dc.titleOptimization of Instrument Design for In-Line Monitoring of Dry Matter Content in Single Potatoes by NIR Interaction Spectroscopyen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.rights.holder© 2021 by the authorsen_US
dc.source.pagenumber14en_US
dc.source.volume10en_US
dc.source.journalFoodsen_US
dc.source.issue4en_US
dc.identifier.doi10.3390/foods10040828
dc.identifier.cristin1903480
dc.relation.projectNofima AS: 11595en_US
dc.relation.projectNorges forskningsråd: 256220en_US
dc.relation.projectNorges forskningsråd: 314111en_US
dc.relation.projectNorges forskningsråd: 309259en_US
dc.relation.projectNofima AS: 202102en_US
dc.source.articlenumber828en_US
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse 4.0 Internasjonal