Vis enkel innførsel

dc.contributor.authorFan, Xiaolei
dc.contributor.authorYu, Tao
dc.contributor.authorLiu, Peng
dc.contributor.authorLi, Xiangdong
dc.date.accessioned2022-09-27T08:37:45Z
dc.date.available2022-09-27T08:37:45Z
dc.date.created2022-08-31T16:42:22Z
dc.date.issued2022
dc.identifier.issn1996-1073
dc.identifier.urihttps://hdl.handle.net/11250/3021654
dc.description.abstractUnderfloor air distribution (UFAD) systems are increasingly used for their advantages in improving energy savings, indoor air quality, and thermal comfort. In UFAD systems, an underfloor plenum delivers conditioned air to the air supply diffusers. The distribution of internal air velocity and static pressure in plenums determines the uniformity of the airflow to the occupied zones. As a result, the plenum has a detrimental effect on the characteristics of the supply air and, thus, the resulting indoor air quality and thermal comfort. Nevertheless, most existing studies on underfloor plenums focused on small-scale plenums with a single internal air duct. Large plenums and multiple air ducts in UFAD equipped in large premises are underexplored. In this study, a circular underfloor plenum with a large scale (radius of 15 m, height difference of 0.9−2.9 m) and 503 under-seat diffusers in a conference room was studied using computational fluid dynamics (CFD) simulation (ANSYS Fluent (16.0)). The distributions of airflow velocity and static pressure inside the plenum were analyzed and compared to one concentrated air supply mode and three uniform air supply modes. Based on the air velocity at the center of under-seat diffusers, the outgoing airflow uniformity from the diffusers under four cases was evaluated by the index of air velocity uniformity. The results showed that the multiple supply ducts with bottom air outlets yielded the best uniformity of supply air. The findings of this paper are expected to provide a technical basis for realizing the optimal design of the UFAD system in terms of uniformity of supply airen_US
dc.language.isoengen_US
dc.publisherMDPIen_US
dc.rightsCC BY 4.0*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectUnderfloor air distributionen_US
dc.subjectCFD simulationen_US
dc.subjectNon-uniformity coefficienten_US
dc.subjectUniform air supplyen_US
dc.titleUniformity of Supply Air in the Plenum for Under-Floor Air Distribution Ventilation in a Circular Conference Room: A CFD Studyen_US
dc.title.alternativeUniformity of Supply Air in the Plenum for Under-Floor Air Distribution Ventilation in a Circular Conference Room: A CFD Studyen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.rights.holder© 2022 The authorsen_US
dc.subject.nsiVDP::Teknologi: 500en_US
dc.source.volume15en_US
dc.source.journalEnergiesen_US
dc.source.issue17en_US
dc.identifier.doi10.3390/en15176370
dc.identifier.cristin2047691
dc.source.articlenumber6370en_US
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

CC BY 4.0
Med mindre annet er angitt, så er denne innførselen lisensiert som CC BY 4.0