Show simple item record

dc.contributor.authorEberg, Espen
dc.contributor.authorKantar, Emre
dc.contributor.authorAakre, Torstein Grav
dc.date.accessioned2022-07-21T10:16:56Z
dc.date.available2022-07-21T10:16:56Z
dc.date.created2022-07-02T14:42:18Z
dc.date.issued2022
dc.identifier.citationProceedings of the Nordic Insulation Symposium. 2022, 27 (1), .en_US
dc.identifier.issn2535-3969
dc.identifier.urihttps://hdl.handle.net/11250/3007497
dc.description.abstractA multi-stress test rig was built to investigate the effect of many start-stops (load cycling) on hydropower generator insulation. To emulate real-life start-stops, stator bars were subjected to accelerated temperature cycling by circulating a 3.5 kA current and then cooling down with fans while high voltage (service voltage) was applied simultaneously to the insulation. A total of 250 load cycles were applied. Partial discharges (PD) were recorded on-line during load cycling, and after every 50 cycles, off-line dielectric loss and PD measurements were conducted. There was an apparent increase in dielectric losses after they had been subjected to a total of 250 load cycles. During load cycling, the PD level generally decreased with temperature, but there was a temporary increase in the PD activity during temperature rise and fall. This trend can be explained by different thermal expansion in copper and insulating material (epoxymica), suggesting that a stator bar that is load-cycled will be exposed to substantially higher PD levels than a stator bar under a uniform load and temperature, leading to further deterioration of the insulation quality.en_US
dc.language.isoengen_US
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleMulti-stress Cyclic Testing of Roebel Stator Bars for Hydropoweren_US
dc.title.alternativeMulti-stress Cyclic Testing of Roebel Stator Bars for Hydropoweren_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.rights.holderThe Authorsen_US
dc.source.pagenumber6en_US
dc.source.volume27en_US
dc.source.journalProceedings of the Nordic Insulation Symposiumen_US
dc.source.issue1en_US
dc.identifier.doi10.5324/nordis.v27i1.4571
dc.identifier.cristin2036865
dc.relation.projectNorges forskningsråd: 255099en_US