Vis enkel innførsel

dc.contributor.authorMenéndez, Esperanza
dc.contributor.authorSilva, António Santos
dc.contributor.authorFernandes, Isabel
dc.contributor.authorDuchesne, Josée
dc.contributor.authorBerra, Mario
dc.contributor.authorDe Weerdt, Klaartje
dc.contributor.authorSalem, Yasmin
dc.contributor.authorGarcía-Roves, Ricardo
dc.contributor.authorSoares, Dora
dc.contributor.authorFournier, Benoit
dc.contributor.authorMangialardi, Teresa
dc.contributor.authorLindgård, Jan
dc.date.accessioned2022-06-09T11:16:05Z
dc.date.available2022-06-09T11:16:05Z
dc.date.created2022-06-07T08:08:32Z
dc.date.issued2022
dc.identifier.issn0465-2746
dc.identifier.urihttps://hdl.handle.net/11250/2998119
dc.description.abstractTo create an international recommendation concerning the release of alkalis, test method AAR-8 was developed within the scope of RILEM TC 258-AAA activities. The first round robin test was performed using five aggregate types, and further investigation was conducted as RRT2, leading to the final version of the AAR-8 recommendation. Five aggregates with different mineralogies and origins were immersed in specific volumes of NaOH or KOH solutions with excess calcium hydroxide maintained 38 °C and 60 °C respectively. Samples of the immersion test solution were removed at intervals of 2, 6, 13, 26, and 52 weeks by pipetting and chemically analyzed for NaOH or KOH test solutions. The amount of alkali released was expressed in grams of Na2O, K2O, and Na2Oe per kilogram of the respective aggregate. The results obtained are presented. Based on the data, several changes to the original version of the test method are proposed.en_US
dc.language.isoengen_US
dc.publisherCSICen_US
dc.rightsCC BY 4.0*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.subjectAlkali-releaseen_US
dc.subjectAggregatesen_US
dc.subjectAlkali-aggregate reactionen_US
dc.subjectChemical compositionen_US
dc.subjectMethodologyen_US
dc.titleRILEM TC 258-AAA Round Robin Test: Alkali release from aggregates and petrographic analysis. Critical review of the test method AAR-8en_US
dc.title.alternativeRILEM TC 258-AAA Round Robin Test: Alkali release from aggregates and petrographic analysis. Critical review of the test method AAR-8en_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.source.volume72en_US
dc.source.journalMateriales de construcciónen_US
dc.source.issue346en_US
dc.identifier.doi10.3989/mc.2022.17021
dc.identifier.cristin2029707
dc.relation.projectNorges forskningsråd: 236661en_US
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

CC BY 4.0
Med mindre annet er angitt, så er denne innførselen lisensiert som CC BY 4.0