Vis enkel innførsel

dc.contributor.authorMonteiro, Juliana
dc.contributor.authorSrivastava, Tanya
dc.contributor.authorRos, Jasper
dc.contributor.authorHuizinga, Arjen
dc.contributor.authorGravesteijn, Paul
dc.contributor.authorVan Os, Peter
dc.contributor.authorDe Vries, Ronald
dc.contributor.authorVos, Mathijs
dc.contributor.authorTelgenkamp, Kirsten
dc.contributor.authorUhre, Susanna Sprauten
dc.contributor.authorSvendsen, Hallvard Fjøsne
dc.contributor.authorKnuutila, Hanna K
dc.date.accessioned2021-10-01T08:26:19Z
dc.date.available2021-10-01T08:26:19Z
dc.date.issued2021
dc.identifier.isbn978-82-536-1714-5
dc.identifier.issn2387-4295
dc.identifier.urihttps://hdl.handle.net/11250/2786893
dc.description.abstractAmine emissions in post combustion CO2 capture (PCC) have a significant impact on process economics and the environment. The volatile nature of amine-based solvents in combination with aerosol formation can lead to amine emissions much higher than the design limit of PCCC plants. Aerosol management methods were implemented at the PCC pilot at Twence, a Waste-to-Energy plant in the east of The Netherlands. TNO carried out measurement campaigns at Twence with the aim to quantify amine emissions (both volatile and aerosol-based). The measurements indicated the necessity of implementing an aerosol mitigation technology, and a Brownian Demister Unit (BDU) was installed at the plant. The BDU removed more than 99% of the small particles (diameter below 5μm) from the flue gas, effectively controlling the MEA emissions at an average of 2.7 mg/Nm3 at the pilot installation outlet.en_US
dc.language.isoengen_US
dc.publisherSINTEF Academic Pressen_US
dc.relation.ispartofTCCS–11. CO2 Capture, Transport and Storage. Trondheim 22nd–23rd June 2021. Short Papers from the 11th International Trondheim CCS Conference
dc.relation.ispartofseriesSINTEF Proceedings;7
dc.rightsCC BY 4.0*
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/*
dc.subjectCO2 Captureen_US
dc.subjectAerosol-Based Emissionsen_US
dc.subjectSolvent Managementen_US
dc.subjectBrownian Demister Uniten_US
dc.titleAerosol Emission at a Post Combustion CO2 Capture Plant at Twence (Wte Facility)en_US
dc.typeChapteren_US
dc.typePeer revieweden_US
dc.typeConference objecten_US
dc.description.versionpublishedVersionen_US
dc.rights.holder© 2021 The Authors. Published by SINTEF Academic Press.en_US
dc.subject.nsiVDP::Teknologi: 500en_US


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

CC BY 4.0
Med mindre annet er angitt, så er denne innførselen lisensiert som CC BY 4.0