Vis enkel innførsel

dc.contributor.authorTümer, Nazlı
dc.contributor.authorKok, Aimee C.
dc.contributor.authorVos, Frans M.
dc.contributor.authorStreekstra, Geert J.
dc.contributor.authorAskeland, Christian
dc.contributor.authorTuijthof, Gabriëlle Josephine Maria
dc.contributor.authorZadpoor, Amir A.
dc.date.accessioned2019-01-16T08:34:14Z
dc.date.available2019-01-16T08:34:14Z
dc.date.created2019-01-15T12:00:02Z
dc.date.issued2018
dc.identifier.citationSensors. 2018, 18 (7), 16nb_NO
dc.identifier.issn1424-8220
dc.identifier.urihttp://hdl.handle.net/11250/2580791
dc.description.abstractA rigid surface–volume registration scheme is presented in this study to register computed tomography (CT) and free-hand tracked ultrasound (US) images of the talocrural joint. Prior to registration, bone surfaces expected to be visible in US are extracted from the CT volume and bone contours in 2D US data are enhanced based on monogenic signal representation of 2D US images. A 3D monogenic signal data is reconstructed from the 2D data using the position of the US probe recorded with an optical tracking system. When registering the surface extracted from the CT scan to the monogenic signal feature volume, six transformation parameters are estimated so as to optimize the sum of monogenic signal features over the transformed surface. The robustness of the registration algorithm was tested on a dataset collected from 12 cadaveric ankles. The proposed method was used in a clinical case study to investigate the potential of US imaging for pre-operative planning of arthroscopic access to talar (osteo)chondral defects (OCDs). The results suggest that registrations with a registration error of 2 mm and less is achievable, and US has the potential to be used in assessment of an OCD’ arthroscopic accessibility, given the fact that 51% of the talar surface could be visualizednb_NO
dc.language.isoengnb_NO
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleThree-dimensional registration of freehand-tracked ultrasound to CT images of the talocrural jointnb_NO
dc.typeJournal articlenb_NO
dc.typePeer reviewednb_NO
dc.description.versionpublishedVersionnb_NO
dc.source.pagenumber16nb_NO
dc.source.volume18nb_NO
dc.source.journalSensorsnb_NO
dc.source.issue7nb_NO
dc.identifier.doi10.3390/s18072375
dc.identifier.cristin1657066
cristin.unitcode7401,90,25,0
cristin.unitnameHelse
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1