dc.description.abstract | The Visund office building is a pilot project within the Research Centre on Zero Emission Buildings (ZEB) in Norway. The building has been in operation since January 2016. The design aimed at meeting the ZEB-criterion of net zero energy balance, excluding energy for appliances. The energy performance has been closely monitored and the energy measurements during the first year corresponds well with the predicted and required performance. A high focus on shared goals, contract based economic incentives, building design and technology choices, energy monitoring and follow-up measures have been key-factors to achieve the goals. | nb_NO |
dc.description.sponsorship | Acknowledgements. This report has been written within the Research Centre on Zero Emission Buildings (www.zeb.no). The authors gratefully acknowledge the support from the Research Council of Norway and the ZEB partners. For the ZEB pilot building Visund, contributions from Forsvarsbygg and Veidekke are especially appreciated. | nb_NO |
dc.language.iso | eng | nb_NO |
dc.rights | CC BY NC ND 4.0 | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/deed.no | * |
dc.subject | Kontorbygning | nb_NO |
dc.subject | Office building | nb_NO |
dc.subject | Energi overvåkning | nb_NO |
dc.subject | Energy monitoring | nb_NO |
dc.subject | Netto null energi | nb_NO |
dc.subject | Net zero energy | nb_NO |
dc.subject | Nullutslippsbygg | nb_NO |
dc.subject | Zero emission buildings | nb_NO |
dc.subject | Norway | nb_NO |
dc.title | Zero emission office building in Bergen: Experiences from first year of operation | nb_NO |
dc.type | Journal article | nb_NO |
dc.type | Peer reviewed | nb_NO |
dc.description.version | publishedVersion | nb_NO |
dc.rights.holder | © 2017 The Authors | nb_NO |
dc.subject.nsi | VDP::Teknologi: 500 | nb_NO |
dc.subject.nsi | VDP::Technology: 500 | nb_NO |
dc.source.pagenumber | 580-585 | nb_NO |
dc.source.volume | 132 | nb_NO |
dc.source.journal | Energy Procedia | nb_NO |
dc.identifier.doi | 10.1016/j.egypro.2017.09.747 | |
dc.identifier.cristin | 1505782 | |
dc.relation.project | Norges forskningsråd: 193830 | nb_NO |
cristin.unitcode | 7401,30,20,0 | |
cristin.unitname | Bygninger og installasjoner | |
cristin.ispublished | true | |
cristin.fulltext | original | |
cristin.qualitycode | 1 | |