Vis enkel innførsel

dc.contributor.authorGrynning, Steinar
dc.contributor.authorSchlemminger, Christian
dc.contributor.authorUvsløkk, Sivert
dc.date.accessioned2017-10-25T07:08:19Z
dc.date.available2017-10-25T07:08:19Z
dc.date.created2017-10-23T13:02:35Z
dc.date.issued2017
dc.identifier.citationEnergy Procedia. 2017, 132 381-386.nb_NO
dc.identifier.issn1876-6102
dc.identifier.urihttp://hdl.handle.net/11250/2461996
dc.description.abstractIn this study, a wood-frame window with an integrated exterior solar shading unit has been investigated. Numerical simulations have been carried out to quantify the moisture distribution and drying-out rate of the construction detail. The simulations have been compared to measured data from an ongoing experimental study. The results indicate that built-in moisture in the wall can lead to high levels of relative humidity (RH) in the detail and that design of this detail should be done considering this. Simulations showed that unfavourable RH-levels can be avoided if it is optimally designed. Preliminary measurements indicate the same trends.nb_NO
dc.language.isoengnb_NO
dc.publisherScienceDirectnb_NO
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/deed.no*
dc.subjectVinduernb_NO
dc.subjectWindowsnb_NO
dc.subjectSolskjermingnb_NO
dc.subjectSolar shadingnb_NO
dc.subjectFuktnb_NO
dc.subjectMoisturenb_NO
dc.subjectScreennb_NO
dc.subjectDrying-out ratenb_NO
dc.subjectNumerical simulationsnb_NO
dc.titleMoisture robustness assessment of a window with integrated solar screen using numerical and experimental methodsnb_NO
dc.typeJournal articlenb_NO
dc.typePeer reviewednb_NO
dc.description.versionpublishedVersionnb_NO
dc.rights.holder© The Authorsnb_NO
dc.subject.nsiVDP::Teknologi: 500nb_NO
dc.subject.nsiVDP::Technology: 500nb_NO
dc.source.pagenumber381-386nb_NO
dc.source.volume132nb_NO
dc.source.journalEnergy Procedianb_NO
dc.identifier.doi10.1016/j.egypro.2017.09.637
dc.identifier.cristin1506820
dc.relation.projectNorges forskningsråd: 255252nb_NO
cristin.unitcode7401,30,40,0
cristin.unitnameArkitektur, byggematerialer og konstruksjoner
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Attribution-NonCommercial-NoDerivatives 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Attribution-NonCommercial-NoDerivatives 4.0 Internasjonal