dc.description.abstractThe motivation for these experiments has been to investigate the influence of a biocompatible protective coating on diaphragm-based in vivo sensors. The investigated device is a resonator for fish identification. Such a diaphragm-based configuration is also commonly used for pressure sensors. Six passive ID tags with a set of acoustic resonators have been coated with a 12 nm thin TiO2 film by the atomic layer deposition (ALD) technique. The frequency response in the 200 kHz to 400 kHz range has been measured in water before and after coating. The resonance peaks can still be detected after coating, but an increase in the resonance frequencies of about 2 % is measured. The increase is explained by a thicker diaphragm due to the TiO2 film.
dc.language.isoengnb_NO
dc.relation.ispartof6th International Workshop on Wearable Micro and Nano Technologies for Personalized Health (pHealth)
dc.titleInvestigations of TiO2 as a protective coating on diaphragm-based in vivo sensorsnb_NO
dc.typeChapternb_NO
dc.source.pagenumber21-24nb_NO
dc.identifier.cristin1451333
cristin.unitcode7401,90,31,0
cristin.unitcode7401,90,32,0
cristin.unitnameMikrosystemer og nanoteknologi
cristin.unitnameInstrumentering
cristin.ispublishedtrue
cristin.fulltextpostprint
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel