Vis enkel innførsel

dc.contributor.authorKhorshidi, Vahid
dc.contributor.authorKriezi, Ekaterini E.
dc.contributor.authorSchlemminger, Christian
dc.contributor.authorHafner, Armin
dc.date.accessioned2022-03-11T14:31:48Z
dc.date.available2022-03-11T14:31:48Z
dc.date.created2021-08-19T10:16:40Z
dc.date.issued2021
dc.identifier.citation10th IIR Conference on Compressors and Refrigerantsen_US
dc.identifier.isbn978-2-36215-039-5
dc.identifier.issn0151-1637
dc.identifier.urihttps://hdl.handle.net/11250/2984740
dc.description.abstractRising concerns for climate change impacts along with the new legislation aimed at lowering emissions indicates the inevitable transition in the cooling/heating industry towards a more energy-efficient solution with minimal environmental impact. Integrated refrigeration, air condition and heat recovery solutions by CO2 (R744) packs are efficient solutions to high energy demanding building (supermarkets and hotels). Proven performance enhancement of Multi Ejector SolutionTM makes the R744 systems more energy efficient, especially in warm climates, compared to the most conventional synthetic refrigerant systems in food retail applications. Pilot installation in the frame of MultiPack, an EU funded project(Horizon 2020), provided a wide range of data, offering the possibility of evaluating the real performance of each ejector group: high pressure (HP), low pressure (LP), and liquid ejector(LE), by running the system in different operating modes. Analysis of the data indicated performance improvement of a system with ejector, on average a 35% lower energy consumption compared to baseline parallel compression R744 system without ejectors. The availability of mass flow measurement from 5 Coriolis mass flow meters on this pilot, enabled the possibility of comparison of mass flow rate in different evaporation temperatures. Data-driven models were used to estimate the performance of ejectors (Entrainment ratio) using onsite data from various operating modes and compare them with the simulated performance from CFD and lab measurements. Careful data pre-processing allows the data-driven model to predict the ejector performance using compressor mass flow rate models trained based on no ejector mode data derived from onsite measurements and compare with models validated by highly accurate lab experiments.en_US
dc.language.isoengen_US
dc.publisherIIRen_US
dc.relation.ispartof10th IIR Conference on Compressors and Refrigerants
dc.relation.ispartofseriesSciences et technique du froid;2021/1
dc.titlePerformance of integrated R744 packs part 2 : ejectors performance, a comparison of data-driven model from onsite measurements with rom model predictionsen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionacceptedVersionen_US
dc.rights.holderIIRen_US
dc.identifier.cristin1927162
dc.relation.projectEU - Horisont Europa: 723137en_US
cristin.ispublishedtrue
cristin.fulltextpostprint
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel