dc.identifier.urihttps://hdl.handle.net/11250/2976107
dc.description.abstractThe RenovActive renovation concept seeks to offer healthy, affordable, easy to reproduce, scalable solutions for the existing building stock of European housing. The concept was developed and tested in a prototype phase, where 7 principles have been applied to a semidetached house built in the 1920s, situated in a garden city in Brussels. The renovated prototype was occupied by a family and monitored for two years. The monitoring was performed, after renovation, both through data, sensors, and extensive interviews and questionnaires with the family. In general, the family living in the house is very satisfied with the indoor environment. The results show a general indoor CO2- concentration below 900 ppm, and an indoor temperature between 21°C and 26°C. The technical and sociological monitoring show indication for the additional potential to optimize and improve indoor comfort levels and perception. As an example, there are discrepancies between setpoints and programming we initiated, based on standards and scientific inputs, based on predicted behaviors. But user interactions, and preferences in real life situation when occupying the house, as well as situational perceptions and culture, modified user setpoints compared to our initial setpoints, that in some settings could have a negative impact on the indoor environment. This indicates that a technical system operating the indoor environment must be both flexible and robust to accommodate for multiple and varying preferences of building inhabitants.
dc.language.isoeng
dc.publisherSINTEF Academic Press
dc.relation.ispartofHealthy Buildings 2021 – Europe. Proceedings of the 17th International Healthy Buildings Conference 21–23 June 2021
dc.relation.ispartofseriesSINTEF Proceedings;9
dc.rightsCC BY 4.0
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.titleHow to transform European housing into healthy and sustainable living spaces using a Belgian case study? – the RenovActive principles tackle climate and renovation challenges
dc.typeChapter
dc.typePeer reviewed
dc.typeConference object
dc.description.versionpublishedVersion
dc.rights.holder© 2021 The Authors. Published by SINTEF Academic Press.