Vis enkel innførsel

dc.contributor.authorAndersen, Hilde
dc.contributor.authorSvendsen, Hedda E.S.
dc.contributor.authorSolum, Stine
dc.contributor.authorYang, Zhilin
dc.contributor.authorTeberikler, Leyla
dc.contributor.authorSolvang, Svein
dc.contributor.authorVreenegoor, Loek
dc.date.accessioned2021-09-21T17:00:16Z
dc.date.available2021-09-21T17:00:16Z
dc.date.issued2021
dc.identifier.isbn978-82-536-1714-5
dc.identifier.issn2387-4295
dc.identifier.urihttps://hdl.handle.net/11250/2780194
dc.description.abstractAn experimental study was carried out on two-phase CO2 flow in Equinor’s multiphase flow rig in Porsgrunn, Norway. This facility was recently upgraded for CO2 applications. This paper presents the experimental results on two-phase regimes of CO2 flow in a pipe close to horizontal inclinations. One of the main discoveries from this work is that hydrodynamic slug flow is not observed. The flow regime information will be used as an input to the model development of flow assurance tools for CO2 applications.en_US
dc.language.isoengen_US
dc.publisherSINTEF Academic Pressen_US
dc.relation.ispartofTCCS–11. CO2 Capture, Transport and Storage. Trondheim 22nd–23rd June 2021 Short Papers from the 11th International Trondheim CCS Conference
dc.relation.ispartofseriesSINTEF Proceedings;7
dc.rightsCC BY 4.0*
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/*
dc.subjectCO2 two-phase flowen_US
dc.subjectFlow regimesen_US
dc.subjectX-ray measurementen_US
dc.titleExperimental Study of Co2 Two-Phase Flow Regime in a Large Diameter Pipeen_US
dc.typeChapteren_US
dc.typePeer revieweden_US
dc.typeConference object
dc.description.versionpublishedVersionen_US
dc.rights.holder© 2021 The Authors. Published by SINTEF Academic Press.en_US
dc.subject.nsiVDP::Teknologi: 500en_US