Show simple item record

dc.contributor.authorStenhagen, Kjersti Refsholt
dc.contributor.authorHolme, Børge
dc.contributor.authorTveit, Anne Bjørg
dc.contributor.authorLussi, Adrian
dc.contributor.authorCarvalho, Thiago Saads
dc.date.accessioned2020-05-07T09:22:51Z
dc.date.available2020-05-07T09:22:51Z
dc.date.created2019-09-05T12:17:59Z
dc.date.issued2019
dc.identifier.citationBMC Oral Health. 2019, 19 (1), 1-9.en_US
dc.identifier.issn1472-6831
dc.identifier.urihttps://hdl.handle.net/11250/2653597
dc.description.abstractBackground There is a need for analytical techniques for measuring Erosive Tooth Wear (ETW) on natural surfaces in clinical studies. The purpose was to investigate the use of two instruments aimed to assess initial to more advanced stages of ETW. Methods Human premolar enamel samples (2x3mm) (n = 24), were polished flat and mounted in resin cylinders (4 cylinders, 6 samples in each). Part 1: Baseline analyses by White Light Interferometer (WLI), Surface Reflection Intensity (SRI: TableTop and OptiPen) and Surface Hardness (SH). Erosion (1% citric acid (pH 3.6) for 1, 2, 4, 6, 8, 10 min. SRI and SH analyses after every erosion episode and by WLI after 10 min. New indentations were made and enamel loss; was measured by change in indentation depths from toothbrush abrasion (200 g, 60 strokes, 30 s). Another series of 2 × 5 min erosion (totally15 min and 20 min) was analysed with SH and SRI after each erosion, and by WLI (on samples and impressions of samples) after 20 min. Part 2 investigated WLI performance in the interface where initial erosion increases in severity and substance loss occurs. The samples were repolished. Baseline analyses by WLI, SRI (TableTop and OptiPen) and SH. Four cylinders were etched for 1, 2, 4, 8 min respectively and analysed by SRI, SH on samples, and WLI on samples and impressions). Results Part1: SRI decreased from baseline to ~ 6 min etch and increased slightly after abrasion, the two devices correlated well (ICC 0.98 p < 0.001, Spearmans rs 0.91 p < 0.001). SH decreased nearly linearly to 10 min etch, but increased distinctly after abrasion. Mean enamel loss from abrasion alone was 0.2 μm (change in indentation depths). After 10 min etch, it was 0.27 μm (WLI) and after 20 min etch, it was 2.2 μm measured on samples vs 2.4 μm on impressions of samples (7% higher). Part 2: From baseline to 8 min etch; SRI and SH decreased whereas WLI presented increasing etch depths. Conclusions With some adjustments, the use of SRI and WLI in combination seems to be a promising strategy for monitoring ETW in clinical studies.en_US
dc.language.isoengen_US
dc.publisherBioMed Centralen_US
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.subjectErosive tooth wearen_US
dc.subjectClinical studiesen_US
dc.subjectMeasurementsen_US
dc.titleAnalytical strategies for clinical studies on dental erosive wearen_US
dc.typeJournal articleen_US
dc.typePeer revieweden_US
dc.description.versionpublishedVersionen_US
dc.rights.holder© The Author(s). 2019 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stateden_US
dc.source.pagenumber1-9en_US
dc.source.volume19en_US
dc.source.journalBMC Oral Healthen_US
dc.source.issue1en_US
dc.identifier.doi10.1186/s12903-019-0834-1
dc.identifier.cristin1721878
cristin.unitcode7401,80,62,0
cristin.unitnameBærekraftig energiteknologi
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode2


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Navngivelse 4.0 Internasjonal
Except where otherwise noted, this item's license is described as Navngivelse 4.0 Internasjonal