Vis enkel innførsel

dc.contributor.authorTaxt, Henning
dc.contributor.authorNiayesh, Kaveh
dc.contributor.authorJonsson, Erik
dc.contributor.authorRunde, Magne
dc.date.accessioned2020-03-20T14:43:47Z
dc.date.available2020-03-20T14:43:47Z
dc.date.created2016-08-24T14:51:27Z
dc.date.issued2016
dc.identifier.citation28th International Conference on Electric Contacts ICEC2016en_US
dc.identifier.isbn978-0-9954659-0-9
dc.identifier.urihttps://hdl.handle.net/11250/2647906
dc.description.abstractThis paper presents a flexible setup to investigate ablation-assisted interruption of load currents. The electrical test circuit is grid connected with a transformer secondary voltage from 6.9 kV to 24 kV. The applied stress to the switching device, such as load current amplitude and transient recovery voltage amplitude and shape, can be set to a large range of values by adjusting the circuit components–resistors, reactors and capacitors–in fine steps. A parallel capacitive-resistive voltage divider ensures high bandwidth and low offset voltage measurements. A resistive shunt is used for current measurement and, in addition, a post-arc current sensor is dedicated to the exact measurement of currents lower than 3 A. The high quality of the measurements allows for a detailed study of the extinction voltage peak, current trace prior to current zero and the post-arc current. Load current interruption measurements from one forced airflow switch and two ablation switches are presented and compared. The ablation switches have a clear current limiting effect close to current zero, whereas the air switch gives a linear decline of the current to zero. One of the ablation switches sustains a post-arc current for 7 ms, without experiencing a re-ignition.en_US
dc.language.isoengen_US
dc.relation.ispartof28th International Conference on Electric Contacts ICEC2016
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/deed.no*
dc.subjectexperimental setupen_US
dc.subjectpost-arc currenten_US
dc.subjectablationen_US
dc.subjectmedium voltageen_US
dc.subjectload-break switchen_US
dc.titleExperimental investigation on ablation-assisted current interruption - Experimental setup and preliminary resultsen_US
dc.typeChapteren_US
dc.description.versionacceptedVersionen_US
dc.source.pagenumber397-401en_US
dc.relation.projectNorges forskningsråd: 235284en_US
cristin.unitcode7548,30,0,0
cristin.unitnameElkraftteknologi
cristin.ispublishedtrue
cristin.fulltextpostprint


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Attribution-NonCommercial-NoDerivatives 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Attribution-NonCommercial-NoDerivatives 4.0 Internasjonal