• A Norwegian ZEB Definition Guideline 

      Fufa, Selamawit Mamo; Schlanbusch, Reidun Dahl; Sørnes, Kari; Inman, Marianne Rose; Andresen, Inger (ZEB Project report;29, Research report, 2016)
      The objective of this report is to provide a comprehensive and consistent guideline for the Norwegian definition of Zero Emission Buildings (ZEB) and the associated calculation methodologies. The guidelines described in ...
    • Erfaringer med bygningsintegrerte solfangere i Norge 

      Simonsen, Ingeborg; Time, Berit; Andresen, Inger (ZEB Project report;2, Research report, 2011)
      Hovedmålet til forskningssenteret ”Zero Emission Buildings” ZEB er å utvikle produkter og løsninger som skal gi oss bygninger med null klimagassutslipp knyttet til produksjon, drift og avhending. Skal vi klare dette må ...
    • Greenhouse gas balances in Zero Emission Buildings – Electricity conversion factors revisited 

      Andresen, Inger; Lien, Kristian Myklebust; Berker, Thomas; Sartori, Igor (ZEB Project report;37, Research report, 2017)
      Reduction of energy use and GHG emissions in the building sector is a high priority. The EU 2050 roadmap that was established in 2010, states that to achieve a global warming of less than 2°C in this century, Europe should ...
    • Mot karbonnøytrale boligområder : Utforming av bygninger og energiforsyning – erfaringer fra pilotprosjekter i Norge 

      Fredriksen, Eyvind; Andresen, Inger (ZEB Project report;18, Research report, 2014)
      Denne rapporten beskriver resultatene fra et prosjekt hvor vi har gjennomgått og diskutert erfaringer fra et utvalg utbyggingsprosjekter i Norge hvor man har hatt spesielt høye ambisjoner med hensyn til energibruk og ...
    • Pilot Building Powerhouse Kjørbo. As Built Report 

      Sørensen, Åse Lekang; Andresen, Inger; Walnum, Harald Taxt; Alonso, Maria Justo; Fufa, Selamawit Mamo; Jenssen, Bjørn; Rådstoga, Olav; Hegli, Tine; Fjeldheim, Henning (ZEB Project report;35, Research report, 2017)
      Powerhouse Kjørbo, located in Sandvika near Oslo, consists of two office blocks from the 1980´s that have been upgraded to energy-efficient and modern offices. The Powerhouse goal is that the refurbished buildings over ...
    • The Visund office building, Haakonsvern, Bergen. As-built report 

      Sørensen, Åse Lekang; Mysen, Mads; Andresen, Inger; Hårklau, Bjarte; Lunde, Arild (ZEB Project report;36, Research report, 2017)
      The Visund office building is a pilot project within the Research Centre on Zero Emission Buildings (ZEB) in Norway. The building has 2031 m2 of heated floor area and is located at Haakonsvern, about 15 km from the centre ...
    • ZEB Pilot Campus Evenstad. Administration and educational building. As-built report 

      Wiik, Marianne Rose Kjendseth; Sørensen, Åse Lekang; Selvig, Eivind; Cervenka, Zdena; Fufa, Selamawit Mamo; Andresen, Inger (ZEB Project report;36, Research report, 2017)
      This report describes the new ZEB Campus Evenstad pilot administration and educational building. The report summarizes and documents the as-built phase life cycle greenhouse gas (GHG) emissions of the administration and ...
    • ZEB pilot Heimdal high school and sports hall. Design phase report 

      Schlanbusch, Reidun Dahl; Fufa, Selamawit Mamo; Andresen, Inger; Wigenstad, Tore; Mjønes, Torger (ZEB Project report;34, Research report, 2017)
      This report summarizes and documents the pre-project competition and design phase life cycle greenhouse gas (GHG) emissions of Heimdal pilot building project. The report describes the calculation methodologies; including ...
    • ZEB pilot house Larvik. As Built Report 

      Sørensen, Åse Lekang; Andresen, Inger; Kristjansdottir, Torhildur; Amundsen, Harald; Edwards, Kristian (ZEB Project report;33, Research report, 2017)
      This report describes the ZEB pilot house Larvik, which was constructed during the autumn 2014. The ZEB pilot house is a two-storey single-family residential building situated near Larvik, Norway. The building was designed ...
    • Zero Village Bergen. Aggregated loads and PV generation profiles 

      Sartori, Igor; Merlet, Stanislas; Thorud, Bjørn; Haug, Thorbjørn; Andresen, Inger (ZEB Project report;28, Research report, 2016)
      The main findings can be summarized as follows: •The aggregated annual thermal load is approximately the same as the electric load (3.3 GWh) for the entire Zero Village Bergen; •The aggregated annual PV generation (2.9 ...
    • Zero Village Bergen. Energy system analysis 

      Sartori, Igor; Skeie, Kristian; Sørnes, Kari; Andresen, Inger (ZEB Project report;40, Research report, 2018)
      Based on discussions with the project partners, three possible solutions have been investigated for the energy system of Zero Village Bergen: 1. District Heating (DH) 2. Biomass fired Combined Heat and Power (Bio ...