Moisture safety strategy for construction of CLT structures in a coastal Nordic climate
Time, Berit; Andenæs, Erlend; Karlsen, Trygve; Geving, Stig; Kvande, Tore (Peer reviewed; Journal article, 2023)To reduce the carbon impact of new buildings, wood is seeing increased use as a structural material. Cross-laminated timber (CLT) and glue-laminated wood (glulam) elements allow the construction of multi-storey buildings. ... -
Moisture-resilient performance of concrete basement walls – Numerical simulations of the effect of outward drying
Asphaug, Silje Kathrin; Andenæs, Erlend; Geving, Stig; Time, Berit; Kvande, Tore (Peer reviewed; Journal article, 2022)The moisture safety designs of basements used for habitation have become a topic of concern. Basements are prone to high moisture strain and have a limited outward drying ability compared with above-grade structures. The ... -
Rain Intrusion through Horizontal Joints in Façade Panel Systems - Experimental Investigation
Støver, Eva Armstrong; Sundsøy, Marte Haugen; Andenæs, Erlend; Geving, Stig; Kvande, Tore (Peer reviewed; Journal article, 2022)Façade panel systems with horizontal open joints are commonly used on larger buildings in Nordic countries. Excessive water intrusion through open joints may cause deterioration of the façade, a concern exacerbated by ... -
Regntette fuger i plan platekledning
Kvande, Tore; Geving, Stig; Time, Berit (Journal article, 2020)Utvendig kledning med plane plater er ei populær fasadekledning spesielt for større bygningar. Vanlegvis blir dei horisontale fugene utført heilt opne, noko som gir mykje regnvatn inn i lufte- og drensspalta. Forsøk i Klima ... -
Slake, luftede tretak med isolerte takflater og innvendig nedløp
Geving, Stig (SINTEF Notat;50, Research report, 2024)Dette notatet beskriver oppbygning av luftede tretak med takvinkel på 10° eller lavere, med vanntett taktekning, isolerte takflater og innvendig nedløp. Slake, luftede tretak med innvendig nedløp er prinsipielt svært likt ... -
Tetting av bygningskroppen ved bruk av teipprodukter
Geving, Stig; Sletnes, Malin; Gullbrekken, Lars; Frank, Susanne Gabriele Martha; Rüther, Petra (SINTEF Fag;102, Research report, 2023)Forord.Denne rapporten oppsummerer resultatene fra kunnskapsprosjektet TightEN – Durable adhesive airtight solutions for energy effective building envelopes (2019–2023). Rapporten er et resultat av omfattende forskningsarbeid ... -
The Effect of Repeated Moisture Cycles on the Air Tightness of Traditional Clamped Vapour Barrier Joints
Geving, Stig; Norvik, Øyvind; Gullbrekken, Lars (Journal article, 2019)In this study it has been investigated whether and to what extent, repeated moisture cycles affect the airleakage through clamped overlap joints in the vapour barrier layer. Use of clamped joints is a traditionalway to ... -
Thermo-fluid dynamic performance of a ventilated pitched roof: Numerical modelling and experimental validation
Moschetti, Roberta; Nocente, Alessandro; Geving, Stig; Gullbrekken, Lars (Peer reviewed; Journal article, 2022)Wooden ventilated pitched roofs represent a widely spread construction solution in Nordic countries. They have several benefits, including the drainage of excessive moisture from the construction and the reduction of the ... -
Utbedring av fuktskadede kjelleryttervegger. Delrapport 1 – Litteraturundersøkelse og generelle anbefalinger
Geving, Stig; Blom, Peter (Prosjektrapport (SINTEF Byggforsk);83, Research report, 2011) -
Utbedring av fuktskadede kjelleryttervegger. Delrapport 2 – Felt-, laboratorie- og beregningsmessige undersøkelser av tre metoder
Geving, Stig; Blom, Peter; Kvalvik, Marius; Martinsen, Espen (Prosjektrapport (SINTEF Byggforsk);84, Research report, 2011)habilitering og utbedring av fuktskadede eksisterende kjelleryttervegger. I denne rapporten er det gjort undersøkelser av tre aktuelle utbedringsmetoder. Det er gjort både fuktberegninger med beregningsprogrammet WUFI, ... -
Vapour retarders in wood frame walls and their effect on the drying capability
Geving, Stig; Holme, Jonas (Journal article; Peer reviewed, 2013)Wood frame walls typically need a vapour barrier at the warm side to avoid interstitial condensation due to vapour diffusion and air leakages from the interior. A more vapour open material than the traditional vapour ... -
Water Vapour Resistance of Ceiling Paints - Implications for the Use of Smart Vapour Barriers in Compact Wooden Roofs
Tomren, Jørgen Haldorsen; Andenæs, Erlend; Geving, Stig; Kvande, Tore (Peer reviewed; Journal article, 2023)Smart vapour barriers enable building envelopes to dry toward the interior side. This property can be used in compact wooden roofs to create more slender structures by placing the wooden load-bearing elements inside the ... -
Å bygge med massivtre i regnvær
Time, Berit; Geving, Stig (Journal article, 2021)ZEB-laboratoriet i Trondheim er bygd med bærekonstruksjon i tre i lunefullt trøndervær. Vi har høstet erfaringer gjennom fuktmålinger i byggeprosessen og følger nå utviklingen i bruksfasen. Byggeplassoppfølgingen viser at ...