Blar i SINTEF Community på emneord "Laboratory measurements"
Viser treff 1-4 av 4
-
Local loss coefficients inside air cavity of ventilated pitched roofs
(Journal article; Peer reviewed, 2018)Pitched roofs with a ventilated air cavity to avoid snow melt and ensure dry conditions beneath the roofing are a widely used construction in northern parts of Europe and America. The purpose of this study has been to ... -
Rain Intrusion through Horizontal Joints in Façade Panel Systems - Experimental Investigation
(Peer reviewed; Journal article, 2022)Façade panel systems with horizontal open joints are commonly used on larger buildings in Nordic countries. Excessive water intrusion through open joints may cause deterioration of the façade, a concern exacerbated by ... -
Thermal Performance of Insulated Constructions—Experimental Studies
(Journal article; Peer reviewed, 2019)Buildings that are designed to meet high-energy performance requirements, e.g., passive houses, require well-insulated building envelopes, with increased insulation thicknesses for roof, wall and floor structures. We ... -
Vapour resistance of wind barrier tape: Laboratory measurements and hygrothermal performance implications
(Peer reviewed; Journal article, 2021)In the building industry, the interest into adhesive tape to achieve a more tight and robust building envelope has increased rapidly in recent years. With an increasing demand for energy efficiency in buildings, national ...