Blar i SINTEF Open på forfatter "Kok, Angela"
-
2nd run of full 3-D detectors
Hansen, Thor-Erik; Kok, Angela; Hansen, Trond Andreas; Lietaer, Nicolas; Jensen, Geir Uri; Summanwar, Anand (Lecture, 2009) -
3D Detector Activities at SINTEF MiNaLab – Wafer Bonding, and Deep Reactive Ion Etching
Kok, Angela (Lecture, 2008) -
3D Radiation Detectors: Charge Collection Characterisation and Applicability of Technology for Microdosimetry
Tran, Linh T.; Prokopovich, Dale A.; Petasecca, Marco; Lerch, Michael L.F.; Kok, Angela; Summanwar, Anand; Hansen, Thor-Erik; Da Via, Cinzia; Reinhard, Mark I.; Rosenfeld, Anatoly B. (Journal article; Peer reviewed, 2014)A study of charge collection in SINTEF 3D active edge silicon detectors was carried out at ANSTO using Ion Beam InducedCharge (IBIC) technique.An IBIC study has shown that several different geometries of 3D detectors have ... -
A solid-state microdosimeter for dose and radiation qualty monitoring for astronauts in space
Peracchi, Stefania; James, Benjamin; Tran, Linh T.; Bolst, David; Prokopovich, Dale A.; Davis, Jeremy; Guatelli, Susanna; Petasecca, Marco; Lerch, Michael L.F.; Matsufuji, Naruhiro; Kok, Angela; Povoli, Marco; Rosenfeld, Anatoly B. (Journal article; Peer reviewed, 2019)This paper presents a study of the response of the silicon on insulator (SOI) microdosimeter with 3-dimensional (3D) sensitive volumes (SV) to 400 MeV/u 16O and 500 MeV/u 56Fe ions mimicking Galactic Cosmic Rays outside ... -
Beam tests of silicon pixel 3D-sensors developed at SINTEF
Dorholt, Ole; Hansen, Thor-Erik; Heggelund, Andreas Løkken; Kok, Angela; Pacifico, Nicola; Røhne, Ole Myren; Sandaker, Heidi; Stugu, Bjarne; Yang, Zongchang; Bomben, Marco; Rummler, André; Weingarten, Jens (Journal article; Peer reviewed, 2018)For the purpose of withstanding very high radiation doses, silicon pixel sensors with a ‘3D’ electrode geometry are being developed. Detectors of this kind are highly interesting for harch radiation environments such as ... -
Design, Simulation, Fabrication, and Preliminary Tests of 3D CMS Pixel Detectors for the Super-LHC
Koybasi, Ozhan; Bortoletto, Daniela; Hansen, Thor-Erik; Kok, Angela; Hansen, Trond Andreas; Lietaer, Nicolas; Jensen, Geir Uri; Summanwar, Anand; Bolla, Gino; Kwan, Simon Wing Lok (Journal article; Peer reviewed, 2010) -
Development and fabrication of full 3D-sensors at SINTEF MiNaLab
Hansen, Thor-Erik; Kok, Angela; Hansen, Trond Andreas; Lietaer, Nicolas; Jensen, Geir Uri; Summanwar, Anand (Lecture, 2009) -
High aspect ratio deep RIE for novel 3D radiation sensors in high energy physics applications
Kok, Angela; Hansen, Thor-Erik; Hansen, Trond Andreas; Jensen, Geir Uri; Lietaer, Nicolas; Mielnik, Michal Marek; Storås, Preben (Journal article; Peer reviewed, 2009)3D detectors with electrodes penetrating through the entire silicon substrate have many advantages over conventional planar silicon technology, for example, high radiation tolerance. High aspect ratio through-wafer holes ... -
In-field and out-of-file application in 12C ion therapy using fully 3D silicon microdosimeters
Tran, Linh T.; Chartier, Lachlan; Bolst, David; Davis, Jeremy; Prokopovich, Dale A.; Pogossov, Alex; Guatelli, Susanna; Reinhard, Mark I.; Petasecca, Marco; Lerch, Michael L.F.; Matsufuji, Naruhiro; Povoli, Marco; Summanwar, Anand; Kok, Angela; Jackson, Michael; Rosenfeld, Anatoly B. (Journal article; Peer reviewed, 2018)This paper presents recent development of Silicon on Insulator (SOI) detectors for microdosimetry at the Centre for Medical Radiation Physics (CMRP) at the University of Wollongong. A new CMRP SOI microdosimeter design, ... -
Latest Results From 2nd SINTEF 3D-Run
Hansen, Thor-Erik; Kok, Angela; Hansen, Trond Andreas; Lietaer, Nicolas; Jensen, Geir Uri; Summanwar, Anand (Lecture, 2009) -
Medical physics aspects of the synchrotron radiation therapies: Microbeam radiation therapy (MRT) and synchrotron stereotactic radiotherapy (SSRT)
Bräuer-Krisch, Elke; Adam, Jean-Francois; Alagoz, Enver; Bartzsch, Stefan; Crosbie, Jeff; DeWagter, Carlos; Dipuglia, Andrew; Donzelli, Mattia; Doran, Simon; Fournier, Pauline; Kalef-Ezra, John; Kok, Angela; Lerch, Michael L.F.; McErlean, Ciara; Oelfke, Uwe; Olko, Pawel; Petasecca, Marco; Povoli, Marco; Rosenfeld, Anatoly B.; Siegbahn, Erik A.; Sporea, Dan; Stugu, Bjarne (Journal article, 2015)Stereotactic Synchrotron Radiotherapy (SSRT) and Microbeam Radiation Therapy (MRT) are both novel approaches to treat brain tumor and potentially other tumors using synchrotron radiation. Although the techniques differ by ... -
Next lot of 3-D detectors at SINTEF
Hansen, Thor-Erik; Kok, Angela; Hansen, Trond Andreas; Lietaer, Nicolas; Mielnik, Michal Marek; storås, Preben; Jensen, Geir Uri (Lecture, 2009) -
Silicon 3D Microdosimeters for Advanced Quality Assurance in Particle Therapy
Tran, Linh T.; David, Bolst; James, Benjamin; Pan, Vladimir M.; Vohradsky, James; Peracchi, Stefania; Chartier, Lachlan; Debrot, Emily; Gautelli, Susanna; Petasecca, Marco; Lerch, Michael L.F.; Prokopovich, Dale A.; Pastuovic, Zeljko; Povoli, Marco; Kok, Angela; Inaniwa, Taku; Lee, Sung Hyun; Matsufuji, Naruhiro; Rosenfeld, Anatoly B. (Peer reviewed; Journal article, 2021)The Centre for Medical Radiation Physics introduced the concept of Silicon On Insulator (SOI) microdosimeters with 3-Dimensional (3D) cylindrical sensitive volumes (SVs) mimicking the dimensions of cells in an array. Several ... -
SOI Thin Microdosimeter Detectors for Low Energy Ions and Radiation Damage Studies
James, B.; Tran, Linh T.; Vohradsky, J.; Bolst, David; Pan, Vladimir M.; Carr, M; Guatelli, Susanna; Pogossov, Alex; Petasecca, Marco; Lerch, Michael; Prokopovich, Dale A.; Reinhard, Mark I.; Povoli, Marco; Kok, Angela; Hinde, D; Dasgupta, M; Stuchbery, A.E.; Perevertaylo, Vladimir I.; Rosenfeld, Anatoly B. (Journal article; Peer reviewed, 2018)The responses of two silicon on insulator (SOI) 3-D microdosimeters developed by the Centre for Medical Radiation Physics were investigated with a range of different low energy ions, with high linear energy transfer (LET). ... -
SOI Thin Microdosimeters for High LET Single Event Upset Studies in Fe, O, Xe and Cocktail Ion Beam Fields
James, Benjamin; Tran, Linh T.; Bolst, David; Perrachi, Stefania; Davis, Jeremy; Prokopovich, Dale A.; Guatelli, Susanna; Petasecca, Marco; Lerch, Michael L.F.; Povoli, Marco; Kok, Angela; Goethem, Marc-Jan; Nancarrow, Mitchell; Matsufuji, Naruhiro; Jackson, Michael; Rosenfeld, Anatoly B. (Journal article; Peer reviewed, 2019)The response of a 5 μm thin silicon on insulator (SOI) 3D microdosimeter was investigated for single event upset applications by measuring the LET of different high LET ions. The charge collection characteristics of the ... -
The relative biological effectiveness for carbon, nitrogen and oxygen ion beams using passive and scanning techniques evaluated with fully 3D silicon microdosimeters
Tran, Linh T.; Bolst, David; Guatelli, S.; Pogossov, A.; Petasecca, Marco; Lerch, Michael L.F.; Chartier, Lachlan; Prokopovich, Dale A.; Reinhard, Mark I.; Povoli, Marco; Kok, Angela; Perevertaylo, Vladimir I.; Matsufuji, Naruhiro; Kanai, T; Jackson, Michael; Rosenfeld, Anatoly B. (Journal article; Peer reviewed, 2018)Background: The aim of this study was to measure the microdosimetric distributions of a carbon pencil-beam scanning (PBS) and passive scattering system as well as to evaluate the relative biological effectiveness (RBE) of ... -
Thin Silicon Microdosimeter utilizing 3D MEMS Fabrication Technology: Charge Collection Study and its application in mixed radiation fields
Tran, Linh T.; Chartier, Lachlan; Prokopovich, Dale A.; Bolst, David; Povoli, Marco; Summanwar, Anand; Kok, Angela; Pogossov, A.; Petasecca, Marco; Guatelli, S.; Reinhard, Mark I.; Lerch, Michael; Nancarrow, Mitchell; Matsufuji, Naruhiro; Jackson, Michael; Rosenfeld, Anatoly B. (Journal article; Peer reviewed, 2017)New 10-μm-thick silicon microdosimeters utilizing 3-D technology have been developed and investigated in this paper. The TCAD simulations were carried out to understand the electrical properties of the microdosimeters’ ... -
Validation of Geant4 for silicon microdosimetry in heavy ion therapy
Bolst, David; Gautelli, Susanna; Tran, Linh T.; Davis, Jeremy; Chartier, Lachlan; Prokopovich, Dale A.; Pogossov, Alex; Reinhard, Mark I.; Petasecca, Marco; Lerch, Michael L.F.; Matsufuji, Naruhiro; Povoli, Marco; Kok, Angela; Summanwar, Anand; Jackson, Michael; Rosenfeld, Anatoly B. (Journal article; Peer reviewed, 2019)Microdosimetry is a particularly powerful method to estimate the relative biological effectiveness (RBE) of any mixed radiation field. This is particularly convenient for therapeutic heavy ion therapy (HIT) beams, referring ... -
Validation of linear energy transfer computed in a Monte Carlo dose engine of a commercial treatment planning system
Wagenaar, David; Tran, Linh T.; Meijers, Arturs; Marmitt, Gabriel Guterres; Souris, Kevin; Bolst, David; Povoli, Marco; Kok, Angela; Traneus, Erik; Van Goethem, Marc-Jan; Langendijk, Johannes A.; Rosenfeld, Anatoly B.; Both, Stefan (Journal article; Peer reviewed, 2019)The relative biological effectiveness (RBE) of protons is highly variable and difficult to quantify. However, RBE is related to the local ionization density, which can be related to the physical measurable dose weighted ...