Vis enkel innførsel

dc.contributor.authorContiero, Luca
dc.contributor.authorHafner, Armin
dc.contributor.authorPardiñas, Ángel Á.
dc.date.accessioned2022-03-11T12:59:38Z
dc.date.available2022-03-11T12:59:38Z
dc.date.created2021-10-01T15:09:28Z
dc.date.issued2021
dc.identifier.citation9th Conference on Ammonia and CO2 Refrigeration Technologies Ohrid, R. Macedonia September 16-17, 2021 Proceedingsen_US
dc.identifier.isbn978-2-36215-046-3
dc.identifier.urihttps://hdl.handle.net/11250/2984683
dc.description.abstractCO2 refrigeration units are gaining market shares thanks to the ability to provide an energy efficient performance for industrial and commercial refrigeration applications in any climate. As with all the applications, the investment and operation costs should be kept as low as possible, to reduce the payback time and promote the introduction of innovative system solutions. In this work the flexibility achieved by implementing the pivoting technology in a supermarket refrigeration application is investigated both at design- and partial load conditions. The air conditioning (AC) load is also considered within a wide range of ambient temperatures. The Multi Ejector block utilized will be analyzed in terms of performance and its effect on the compressor combinations at different operating conditions. The objective is to increase the flexibility of the centralized rack through a proper design and sizing of the compressor pack equipped with the pivoting technology, while maintaining the efficiency and reducing the investment costs. This work shows that a Multi Ejector pivoting-supported system will be beneficial from the flexibility and capital costs point of view, and the benefit will be more consistent if the AC load is part of the integrated system architecture. Furthermore, a thorough investigation has been conducted whenever the ejector capacity is too high compared to the load, proposing two alternative solutions.en_US
dc.language.isoengen_US
dc.publisherIIRen_US
dc.relation.ispartof9th Conference on Ammonia and CO2 Refrigeration Technologies Ohrid, R. Macedonia September 16-17, 2021 Proceedings
dc.titleMulti Ejector and pivoting-supported R744 application with AC for supermarketsen_US
dc.typeChapteren_US
dc.typePeer revieweden_US
dc.description.versionacceptedVersionen_US
dc.rights.holderIIRen_US
dc.source.pagenumber148-160en_US
dc.identifier.cristin1942338
dc.relation.projectNorges forskningsråd: 257632en_US
cristin.ispublishedtrue
cristin.fulltextpostprint
cristin.qualitycode1


Tilhørende fil(er)