Vis enkel innførsel

dc.contributor.authorXie, Zichan
dc.contributor.authorBivolarova, Mariya P.
dc.contributor.authorMelikov, Arsen K.
dc.date.accessioned2022-01-31T18:04:29Z
dc.date.available2022-01-31T18:04:29Z
dc.date.issued2021
dc.identifier.isbn978-82-536-1728-2
dc.identifier.issn2387-4295
dc.identifier.urihttps://hdl.handle.net/11250/2976124
dc.description.abstractNumerous studies on ventilation of general patient rooms have been performed, while most of the studies have focused on total volume air distribution (mixing or displacement). This study presents results of local ventilation (LV) aimed to efficiently protect a lying person from cross-infection due to airborne respiratory viruses. Experiments performed in a climate chamber (4.7 m × 4.7 m × 2.6 m) included LV when used alone and when coupled with background mixing ventilation (MV). A thermal manikin and a heated standing dummy were used to simulate respectively a patient lying in bed and an infected doctor or nurse standing beside the bed. The LV was able to reduce substantially the exposure of the patient to the infected air exhaled by the doctor. The results show that the efficiency of the LV depended mostly on its supply airflow rate. An increase of the background ventilation's supply flow rate, i.e. increase of the air change rate in the room, was less important. At 15 L/s supplied by LV the concentration of a contaminant at the patient's mouth decreased by 76%. The findings of the paper give insights for researchers and designers in developing a novel ventilation system to be used during a pandemic in general patient rooms.
dc.language.isoeng
dc.publisherSINTEF Academic Press
dc.relation.ispartofHealthy Buildings 2021 – Europe. Proceedings of the 17th International Healthy Buildings Conference 21–23 June 2021
dc.relation.ispartofseriesSINTEF Proceedings;9
dc.rightsCC BY 4.0
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectCombined ventilation system
dc.subjectCrossinfection
dc.subjectVentilation efficiency
dc.subjectThermal comfort
dc.titleLocal ventilation for general patient rooms
dc.typeChapter
dc.typePeer reviewed
dc.typeConference object
dc.description.versionpublishedVersion
dc.rights.holder© 2021 The Authors. Published by SINTEF Academic Press.