Vis enkel innførsel

dc.contributor.authorPadayachy, Llewellyn
dc.contributor.authorBrekken, Reidar
dc.contributor.authorFieggen, Graham
dc.contributor.authorSelbekk, Tormod
dc.date.accessioned2019-04-09T06:25:06Z
dc.date.available2019-04-09T06:25:06Z
dc.date.created2019-02-15T15:36:32Z
dc.date.issued2018
dc.identifier.issn2332-4252
dc.identifier.urihttp://hdl.handle.net/11250/2593770
dc.description.abstractBACKGROUND: Measurement of optic nerve sheath diameter (ONSD) is a promising technique for noninvasive assessment of intracranial pressure (ICP), but has certain limitations. A recent study showed that the deformability index (DI), a dynamic parameter quantifying the pulsatile nature of the optic nerve sheath, could differentiate between patients with high vs normal ICP. OBJECTIVE: To further evaluate the diagnostic accuracy of the DI, when interpreted together with ONSD. METHODS: This prospective study included children undergoing invasive ICP measurement as part of their clinical management. Ultrasound images of the optic nerve sheath were acquired prior to measuring ICP, the images were further processed to obtain the DI. Patients were dichotomized into high (≥20 mm Hg) or normal ICP groups and compared using the Mann-Whitney U-test. Diagnostic accuracy was described using area under the receiver operating characteristic curve (AUC), sensitivity and specificity, correlation between DI, ONSD, and ICP was investigated using linear regression. RESULTS: A total of 28 patients were included (19 high ICP). The DI was lower in the high ICP group (0.105 vs 0.28, P = .001). AUC was 0.87, and a cut-off value of DI ≤ 0.185 demonstrated sensitivity of 89.5% and specificity of 88.9%. Diagnostic accuracy improved when combining DI with ONSD (AUC 0.98, sensitivity 94.7%, specificity 88.9%) and correlation with ICP improved when combined analysis of DI and ONSD was performed (Pearson correlation coefficient: 0.82 vs 0.42, respectively, P = .012). CONCLUSION: The DI was significantly lower for patients with high vs normal ICP. This relationship improved further when the DI and ONSD were interpreted together.nb_NO
dc.language.isoengnb_NO
dc.titleNoninvasive Transorbital Assessment of the Optic Nerve Sheath in Children: Relationship Between Optic Nerve Sheath Diameter, Deformability Index, and Intracranial Pressurenb_NO
dc.typeJournal articlenb_NO
dc.typePeer reviewednb_NO
dc.description.versionacceptedVersionnb_NO
dc.source.journalOperative Neurosurgerynb_NO
dc.identifier.doi10.1093/ons/opy231
dc.identifier.cristin1677831
dc.relation.projectNorges forskningsråd: 260702nb_NO
cristin.unitcode7401,90,25,0
cristin.unitnameHelse
cristin.ispublishedtrue
cristin.fulltextpostprint
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel