Accuracy of electromagnetic tracking with a prototype field generator in an interventional OR setting

Bø, Lars Eirik; Leira, Håkon Olav; Tangen, Geir Arne; Hofstad, Erlend Fagertun; Amundsen, Tore; Langø, Thomas
Journal article, Peer reviewed
Thumbnail
View/Open
accuracy_MP_postprint.pdf (51.07Mb)
Permanent link
http://hdl.handle.net/11250/2593690
Issue date
2012
Metadata
Show full item record
Collections
  • Publikasjoner fra CRIStin - SINTEF AS [2636]
  • SINTEF Teknologi og samfunn [556]
Original version
Medical physics (Lancaster). 2012, 39 (1), 399-406.   10.1118/1.3666768
Abstract
Purpose: The authors have studied the accuracy and robustness of a prototype electromagnetic window field generator (WFG) in an interventional radiology suite with a robotic C-arm. The overall purpose is the development of guidance systems combining real-time imaging with tracking of flexible instruments for bronchoscopy, laparoscopic ultrasound, endoluminal surgery, endovascular therapy, and spinal surgery. Methods: The WFG has a torus shape, which facilitates x-ray imaging through its centre. The authors compared the performance of the WFG to that of a standard field generator (SFG) under the influence of the C-arm. Both accuracy and robustness measurements were performed with the C-arm in different positions and poses. Results: The system was deemed robust for both field generators, but the accuracy was notably influenced as the C-arm was moved into the electromagnetic field. The SFG provided a smaller root-mean-square position error but was more influenced by the C-arm than the WFG. The WFG also produced smaller maximum and variance of the error. Conclusions: Electromagnetic (EM) tracking with the new WFG during C-arm based fluoroscopy guidance seems to be a step forward, and with a correction scheme implemented it should be feasible.
Journal
Medical physics (Lancaster)

Contact Us

Privacy policy
Powered by DSpace software

Service from Unit
 

 

Browse this CollectionIssue DateAuthorsTitlesSubjectsDocument TypesJournalsBrowse ArchiveCommunities & CollectionsIssue DateAuthorsTitlesSubjectsDocument TypesJournals

My Account

Login

Statistics

View Usage Statistics

Contact Us

Privacy policy
Powered by DSpace software

Service from Unit