dc.description.abstractThis paper presents the finite element analysis (FEA) results of a multi-story reinforced concrete (RC) building having precast and cast-in-place load bearing walls. Door-type cut-out openings (height: 2.1 m, width: 0.9–4.4 m) were created at the first and second story of the building. Results from experimental tests on axially loaded RC panels were used to verify the modeling approach. The influence of cut-out openings on the response of individual RC panels, failure modes, and load redistribution to adjacent members under increasing gravitational loads was analyzed. Moreover, the wall bearing capacities obtained from FEA were compared with the values calculated from design equations. The results revealed that the robustness of multi-story buildings having RC load bearing wall systems decrease considerably with the creation of cut-out openings. However, owing to the initial robustness of the buildings, large cut-out openings could be created under normal service conditions without strengthening of the building structure. Furthermore, design equations provided very conservative predictions of the ultimate axial capacity characterizing the solid walls and walls with small openings, whereas similar FEA and analytically predicted capacities were obtained for walls with large openings.
dc.language.isoengnb_NO
dc.relation.urihttps://www.sciencedirect.com/science/article/pii/S0141029618324027
dc.subjectCut-out openings
dc.subjectLoad bearing walls
dc.subjectReinforced concrete
dc.titleLocal and global behavior of walls with cut-out openings in multi-story reinforced concrete buildingsnb_NO
dc.typeJournal articlenb_NO
dc.typePeer reviewednb_NO
dc.description.versionsubmittedVersion
dc.subject.nsiVDP::Bygningsmaterialer: 525
dc.subject.nsiVDP::Building materials: 525
dc.source.pagenumber57-72nb_NO
dc.source.volume187nb_NO
dc.source.journalEngineering structuresnb_NO
dc.identifier.doi10.1016/j.engstruct.2019.02.046
dc.identifier.cristin1703178
dc.relation.projectEU/Contract number MC-ITN-2013-607851nb_NO
dc.relation.projectAndre: Development fund of the Swedish Construction Industry (SBUF)nb_NO
cristin.unitcode6228,0,0,0
cristin.unitnameNorut Northern Research Institute Narvik AS
cristin.ispublishedtrue
cristin.fulltextpreprint
cristin.qualitycode2


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel