Comparison of Levelized Cost of Energy of superconducting direct drive generators for a 10 MW offshore wind turbine
Abrahamsen, Asger B; Liu, Dong; Magnusson, Niklas; Thomas, Arwyn Sean; Azar, Ziad; Stehouwer, Ewoud; Hendriks, Ben; Zinderen, Gerrit Jan Van; Deng, Fujin; Chen, Zhe; Karwatzki, Dennis; Mertens, Axel; Parker, Max Alexander; Finney, Stephen Jon; Polinder, Henk
Journal article, Peer reviewed
Accepted version
Permanent lenke
http://hdl.handle.net/11250/2585098Utgivelsesdato
2018Metadata
Vis full innførselSamlinger
- Publikasjoner fra CRIStin - SINTEF Energi [1614]
- SINTEF Energi [1731]
Originalversjon
10.1109/TASC.2018.2810294Sammendrag
A method for comparing the Levelized Cost of Energy (LCoE) of different superconducting drive trains is introduced. The properties of a 10 MW MgB$_{2}$ superconducting direct drive generator are presented in terms weight scaled to a turbine with a rotor diameter up of 280 m and the cost break down of the nacelle components. The partial load efficiency of the generator is evaluated for a constant cooling power of 0, 50 kW and 100 kW and the annual energy production is used to determine the impact on Levelized Cost of Energy. Copyright IEEE Comparison of Levelized Cost of Energy of superconducting direct drive generators for a 10 MW offshore wind turbine